G8MNY > TECHNI 15.06.26 09:33l 88 Lines 4333 Bytes #999 (0) @ WW
BID : 62484_GB7CIP
Read: GAST
Subj: Eagle DB120 Sound Meter
Path: DB0FFL<OE2XZR<OK1TOR<SR6DWH<SR1BSZ<OK0NBR<OK2PEN<GB7CIP
Sent: 260615/0633Z @:GB7CIP.#32.GBR.EURO #:62484 [Caterham Surrey GBR]
From: G8MNY@GB7CIP.#32.GBR.EURO
To : TECH@WW
By G8MNY (Correction Feb 16)
(8 Bit ASCII graphics use code page 437 or 850, Terminal Font)
The is a simple cheap sound meter.
____ PCB LAYOUT
ÚÄÄÄÁÄÄÄÄÁÄÄÄ¿ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
³³~~~~~~~~~~³³ ³ /~~~\ ³
³³ \ ³³ ³Q12³METER³VR2³
³³ \ ³³ ³ \___/ ³
³³__________³³ 40dBA-120dBA in 2 ranges ³ ³
³ ____³ In built calibrator ³VR1 __ ³
³ /~~\ ³ ³Ú¿ Q5 /~ ~\³
³ ³ ³³ ³³³ ³SWITCH³
³ \__/ ³ ³³³IC \_ _/³
³ ~~~~³ ³ÀÙ VR3 ~~ ³
³ ³ ³ ³
³ EAGLE ³ À¿ ÚÄÄÄ¿ ÚÙ
³ ³ ³VR5³ ³VR4³
³ ³ ÀÄÄÄÙ ÀÄÄÄÙ
ÀÄÄÄÄÄÄÄÄÄÄÄÄÙ
CIRCUIT
ÚÄÄÄÄÄÂÄÄÄÂÄÄÄÂÄÄÄÄ2K2ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÂÄ<+ve
³ 56K ³ ³ ³ ³ OPAMP
³ + ³ ³/ ³+ ³ ³ The TD7120 provides
MicÄ´ÃÄÅÄ´Q3 === ³ 56K fixed stable gain
³ 4u7 ³ ³\e ³33u 7³ ÚÄÄÄ¿ ³ to drive the non the
³ 56K ³ ³ Low 2³~\³3 56K ³ linear metering stage.
³ ³ VR2ÃÄ)ÄÂÄÄÄÄÄÄÄo<Ä2K2ÄÄÂÄÄÄ´TA\ 6³ ³ +
³ ³ Mic ³14K4 150K ³7120>ÄÁÄÄÄÄ)ÄÄ´ÃÄÄ3K3Ä>
³ ³ cal ³ ÃÄÄÄÄÄÄÄo ÃÄÄÄ´ /ÀÄÂÄ19KÄ´+ 10u
³ ³ ³ ³220R High +³ 5³_/ 1 ³ ===
³ ³ ³ ³ ³ 10u=== ³4 ===3n3 ³10u
ÀÄÄÄÄÄÁÄÄÄÁÄÄÄÁÂÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÁÄÄÄÄÁÄÄÄÄÄÁÄ<
ÀÄÄVR1ÄÄÂo Cal
200R ³ ÚÄÄÄÄÂÄÄÄÂÄÄÄÄÂÄÄ5K1ÄÄ<+ve
220K ³ 33K 33K ³
PREAMPS ³ 3K9 ³ ³ 3K9
The 3 wire electret mic ÀÄÄÄÄÅÄÄ´ÃÁ\ /Á´ÃÄÄ´
and preamp Q3 is powered \³ X ³/
from a decoupled rail. Q2ÃÄÄÄÙ ÀÄÄÄ´Q1
e/³ ASTABLE ³\e
VR2 calibrates the mic ÀÄÄÄÄÄÄÂÄÄÄÄÄÄÙ
capsule and VR1 calibrates 100R
the astable calibrate ÄÄÁÄÄÄ<
oscillator Q1&2.
METER DRIVER oOff
+ve<ÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄ¿e ÚÄÄÂÄÄÂÄo<ÄÄÄÂÄÄ¿
10K ³/ 47u³+ \ / 2K2 ÃÄoHigh³ ³
ÃÄÄ´Q5 === ÄÄÂÄÄ ³ ÀÄoCal ³ ³
_³_ ³\e +10u ³ Q7ÃÄÄÄÄÙ ÚÄoBat ³ ³
\_/ ÃÄÄÄ560RÄÄÂÄ´ÃÄÄÂÄÄÄ¿ ³ ³ ³ oOff³ ³
_³_ ÃÄÄ¿ +³ ³ ³ ³ ³ ³ ³ ³
D1 \_/ ³/e ³ ===10u ³ ³ ³ _³_ ³ ³ ³
ÚÄ´>ÃÄ¿ ÃÄÄ´Q6 100K ³ ³ ³ ³ /_\' ³ === ³+
³ ³ ³/ ³\ ³ ÚÄÁÄ¿ ³ ³ ³ ³ ³ ³ BATT
>ÄÅÄ2K2ÄÅÄÄÂÄÄÄ´Q4 ³ ³ _³_ _³_ _³_ _³_ ³ ³ ³ ³ PP3
³ ³ 100k ³\e ³ ³ \_/ /_\ \_/ /_\ ³ ³ ÃÄÄÄ¿ ³ ³
ÀÄ´<ÃÄ´ ÀÄÄÄÄÄ)ÄÄÄÄ)ÄÄ´+ ³D9 ³D8 ³D7 ³D6³ ³ VR3 680R³ ³
D2 ³ 220R ³ === ³ ³ ³ ³ ³ ³ 50K ³ ³ ³
³ ³ ³ ³10u ³ ³ ³ ³ ³ ³ ³ ³ ³ ³
<ÄÄÄÄÄÄÄ)ÄÄÄÄÄÄÂÄÁÄÄÄÄÁÂÄÁÄÄÄÄ)ÄÄÄÁÄÄÄÁÄÄÄ)ÄÄÁÄÄÄÄÁÄÄÄÄÄÄÄ)ÄÄÄÁÄÄÁÄÄÙ
³ 10u=== ===10u ³ ³ ³
D3ÃÄ´<ÃÄÄÁÄÄVR5ÄÄÁÄÄÄÄÄÄÁÄÄÄ´>ÃÄÄÄÄÄ)ÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄ´
³ 5K D10 ³ VR4 33u=== Meter
D4ÀÄ´>ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄ2KÄÄÄÄÄÁÄÄÄÄÄÙ
To get a usable 40dB scale on a meter quite a lot of compression is needed.
This circuit uses an AGC approach. Transistors Q4, 5 & 6 from a power amp to
drive the double voltage doubler bridge D6-10 rectified load of the meter and
also provide AGC with D3 & D4 making an variable input attenuator.
VR5 set the AGC log action and diodes D1 & D2 correct for over compression to
get the very linear 40dB scale. VR4 is the main calibrate and VR3 is the
battery cal.
See my bul on "Sound Levels dBA dBB dBC".
Why don't U send an interesting bul?
73 de John G8MNY @ GB7CIP
Lese vorherige Mail | Lese naechste Mail
| |